From eave to ridge w.
Ground snow load to roof snow load conversion.
Version 0 1 0 september 25 2020.
Length of low roof ll.
Roof snow load and the applicable snow.
In my region on cape cod we have a ground snow load design of 25 psf which is a greater design load than the live load 12 psf to 20 psf over an entire roof system.
Snow load factors are critically examined for use in load and resistance factor design lrfd.
The snow load that is applied to our structure is not the ground snow load but in most cases the flat roof snow load.
In other words on a steep roof less material would be stacked in a concentrated area at one time to avoid having it slide off.
Other considerations for sloped roofs can be found throughout chapter 7 of asce 7 10.
Length of roof upwind of the snow drift.
This web based application is made freely available courtesy of the advertisements displayed on this page.
The flat roof snow load is calculated using formula 7 3 1.
Medeek design assumes no liability or loss for any designs presented and does not guarantee fitness for use.
The ansi snow load subcommittee took advantage of this new information to update and improve calculation of roof snow loads.
Nsf 8 9 have shed new light on the ground to roof conversion factor.
If the ground snow load isn t specified then a ground snow load needs to be assumed and the truss designer and the building designer may not be on the same page as it relates to this design assumption.
Length of roof downwind of the snow drift.
Rain load s r.
Roof snow load nbc 2010 roof snow load nbc 2010 version 0 1 0 september 25 2020.
If you live in the us our snow load calculator compares the total weight on your roof with the permissible load calculated according to the standards issued by the american society of civil engineers regarding the minimum design loads for buildings and other structures asce7 16.
If your roof is 1 000 square feet the total snow load is 15 000 pounds of snow.
Ground snow load s s.
Even when the specification is clear regarding ground snow vs.
If the snow weighs 10 pounds per cubic foot and there are 1 5 feet on the roof each square foot of the roof is getting 15 pounds of pressure.
Specifically examined are the effects on structural reliability of the change in the basic ground load to roof load conversion factor from 0 8 to 0 7 and recent statistical data concerning the conversion factor.
Horizontal distance from eave to ridge.
Asce 7 drift height calculation.
Length of high roof lu.
Our recommendations on ground to roof conversion factors incorporates what we consider to be the most accurate information on the topic.
Figure 7 1 pages 84 85 and table 7 1 page 92.
To figure out the load on your roof take the depth of snow in feet and multiply it by the weight of a cubic foot of snow.
Ground snow load pg.