Class a does not mean grade a roofing systems are rated by realistic fire tests.
Gar roofing class a fire ratings.
Building code fire resistance requirements building codes establish fire resistance requirements for roofs based on the type of construction e g concrete steel wood for the building.
In a recent roofing column we focused upon technical information that could be found on roofing material wrappers that could verify compliance with various building codes.
Set custom price range.
Highest roofing fire rating.
According to the scope of fm 4470.
Class a roofing is the preferred choice for any home but this type of roofing is particularly important if you live in an area that is prone to wildfires to achieve a class a rating the roof must be effective against severe fire exposure.
The slope of the test specimen is preselected and since steeper slopes are more of a challenge due to melting material feeding the fire the rating applies to the maximum slope passed.
In some jurisdictions roof assemblies are required to be fire resistant.
Fire rating ul 790 class a 56 no rating available 1 price.
Common underlying materials include a type 72 roll roofing material also known as 72 pound felt or 72 pound capsheet material and a panelized gypsum product.
Truck tool rental.
Versashield fire resistant roof deck protection provides the very best fire protection.
Tested roof systems are fire classified class a b or c where the most fire resistant roof assemblies are class a and class c is least resistant.
1 1 2 c 1 1 2 x 25 32 block of wood with one saw kerf on the wood block.
When installed with the required combination of gaf accessories timberline hdz shingles are eligible for an industry first.
Windproven limited wind warranty.
Get free shipping on qualified class a roof shingles or buy online pick up in store today in the building materials department.
This month let s take a closer look at one particular type fire ratings.
A wind warranty with no maximum wind speed limitation.
Versashield fire resistant roof deck protection is a key part of the gaf lifetime roofing system 1 and has earned the good housekeeping seal.
Understanding roof fire ratings class a roofing.
The maximum flame spread is 6 feet for a class a rated roof 8 feet for class b and 13 feet for class c.
Class c roof coverings are not readily flammable are effective against light fire exposures and do not readily carry or communicate fire.
An exterior fire retardant treated shake roof has a stand alone class b rating.
The best rating achieved is class a which is described by ul as effective against severe fire exposure class 1 rating.
Example test process for class c fire protection rating.
The class 1 rating is an exclusive designation that can only be awarded by fm global which indicates the successful testing of the entire roof assembly using fm approval standard 4470.
Ul class a listed to ansi ul 790.